Winters, LM7060, LM7 0/60 PSI General Purpose Submersible Pressure Transmitter
Applications:
- Appropriate for all level and depth measurement applications including open tanks, ground water monitoring, sewage and water treatment facilities
Description & Features:
- Designed for continuous level measurement in water or waste water (thin film)
- Good linearity for long term stability
- Available ranges up to 300 psi
- Wide range of mechanical and electrical connections
- +/-0.5% accuracy
- NEMA 6P / IP68. Approved for outdoor use
- Customizable
- RoHS compliant
- 1 year warranty
| Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 VdcOptional 3-wire: 0-20 mA / Vs = 14-30 Vdc 0-10 V / Vs = 14-30 Vdc |
| Accuracy |
?+/-0.5% FSO |
| Permissible Load |
Current 2-wire: Rmax = [(Vs – Vs min) / 0.02] OhmCurrent 3-wire: Rmax = 500 OhmVoltage 3-wire: Rmin = 10 kOhm |
| Influence Effects |
Supply: 0.05% FSO / 10 VLoad: 0.05% FSO / kOhm |
| Response Time |
?10 ms |
| Thermal Error |
?+/-0.2% FSO / 10K |
| PermissibleTemperatures |
Medium: 14°F to 158°F (-10°C to 70°C)Storage: -13°F to 158°F (-25°C to 70°C) |
| Short Circuit Protection |
Permanent |
| Reverse Polarity Protection |
No damage. No function. |
| Electromagnetic Protection |
Emission and immunity according to EN 61326 |
| Connecting Cables |
Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/mCable inductance: Signal line/shield and signal line/signal line: 1 ?H/m |
| Electrical Connection |
Cable with sheath material: PVC grey, PUR black, FEP black |
| Pollution Degree |
4, electrical equipment for outdoor use |
| Housing |
316L SS |
| Seals |
FKM (Viton, Kalrez) / EPDM |
| Diaphragm |
Ceramic AI2O396% |
| Protection Cap |
POM |
| Current Consumption |
Current: 25 mA maxVoltage: 7 mA max |
| Weight |
250 g (without cable) |
| Enclosure Rating |
NEMA 6P / IP68 |
| CE Conformity |
EMC directive: 2004/108/EC |
</table